feat(vbat): update vbat charger threshold on p4 revision 3

This commit is contained in:
C.S.M
2026-01-16 11:28:26 +08:00
parent ca22d0e8ec
commit b21e7bda23
@@ -89,9 +89,9 @@ menu "Power Supplier"
Use this option carefully to avoid damage to non-rechargeable batteries. Use this option carefully to avoid damage to non-rechargeable batteries.
choice ESP_VBAT_DET_LVL_LOW_SEL choice ESP_VBAT_DET_LVL_LOW_SEL
prompt "VBAT start charging voltage level" prompt "VBAT start charging voltage level (P4 revision < v3.0)"
default ESP_VBAT_DET_LVL_LOW_SEL_6 default ESP_VBAT_DET_LVL_LOW_SEL_6
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && ESP32P4_SELECTS_REV_LESS_V3
help help
The brownout detector will start charging when the supply voltage drops below the selected threshold. The brownout detector will start charging when the supply voltage drops below the selected threshold.
This ensures that the power supply is maintained at a stable level. This ensures that the power supply is maintained at a stable level.
@@ -104,10 +104,26 @@ menu "Power Supplier"
bool "2.42V" bool "2.42V"
endchoice endchoice
choice ESP_VBAT_DET_LVL_LOW_SEL_V3
prompt "VBAT start charging voltage level (P4 revision >= v3.0)"
default ESP_VBAT_DET_LVL_LOW_SEL_6_V3
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && !ESP32P4_SELECTS_REV_LESS_V3
help
The brownout detector will start charging when the supply voltage drops below the selected threshold.
This ensures that the power supply is maintained at a stable level.
config ESP_VBAT_DET_LVL_LOW_SEL_7_V3
bool "2.84V"
config ESP_VBAT_DET_LVL_LOW_SEL_6_V3
bool "2.74V"
config ESP_VBAT_DET_LVL_LOW_SEL_5_V3
bool "2.64V"
endchoice
choice ESP_VBAT_DET_LVL_HIGH_SEL choice ESP_VBAT_DET_LVL_HIGH_SEL
prompt "VBAT stop charging voltage level" prompt "VBAT stop charging voltage level (P4 revision < v3.0)"
default ESP_VBAT_DET_LVL_HIGH_SEL_7 default ESP_VBAT_DET_LVL_HIGH_SEL_7
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && ESP32P4_SELECTS_REV_LESS_V3
help help
The brownout detector will stop charging when the supply voltage arrives the selected threshold. The brownout detector will stop charging when the supply voltage arrives the selected threshold.
@@ -119,6 +135,21 @@ menu "Power Supplier"
bool "2.42V" bool "2.42V"
endchoice endchoice
choice ESP_VBAT_DET_LVL_HIGH_SEL_V3
prompt "VBAT stop charging voltage level (P4 revision >= v3.0)"
default ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && !ESP32P4_SELECTS_REV_LESS_V3
help
The brownout detector will stop charging when the supply voltage arrives the selected threshold.
config ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
bool "2.84V"
config ESP_VBAT_DET_LVL_HIGH_SEL_6_V3
bool "2.74V"
config ESP_VBAT_DET_LVL_HIGH_SEL_5_V3
bool "2.64V"
endchoice
choice ESP_VBAT_BROWNOUT_DET_LVL_SEL choice ESP_VBAT_BROWNOUT_DET_LVL_SEL
prompt "VBAT brownout voltage level" prompt "VBAT brownout voltage level"
default ESP_VBAT_BROWNOUT_DET_LVL_SEL_5 default ESP_VBAT_BROWNOUT_DET_LVL_SEL_5
@@ -144,16 +175,16 @@ menu "Power Supplier"
config ESP_VBAT_DET_LVL_LOW config ESP_VBAT_DET_LVL_LOW
int int
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
default 5 if ESP_VBAT_DET_LVL_LOW_SEL_5 default 5 if ESP_VBAT_DET_LVL_LOW_SEL_5 || ESP_VBAT_DET_LVL_LOW_SEL_5_V3
default 6 if ESP_VBAT_DET_LVL_LOW_SEL_6 default 6 if ESP_VBAT_DET_LVL_LOW_SEL_6 || ESP_VBAT_DET_LVL_LOW_SEL_6_V3
default 7 if ESP_VBAT_DET_LVL_LOW_SEL_7 default 7 if ESP_VBAT_DET_LVL_LOW_SEL_7 || ESP_VBAT_DET_LVL_LOW_SEL_7_V3
config ESP_VBAT_DET_LVL_HIGH config ESP_VBAT_DET_LVL_HIGH
int int
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
default 5 if ESP_VBAT_DET_LVL_HIGH_SEL_5 default 5 if ESP_VBAT_DET_LVL_HIGH_SEL_5 || ESP_VBAT_DET_LVL_HIGH_SEL_5_V3
default 6 if ESP_VBAT_DET_LVL_HIGH_SEL_6 default 6 if ESP_VBAT_DET_LVL_HIGH_SEL_6 || ESP_VBAT_DET_LVL_HIGH_SEL_6_V3
default 7 if ESP_VBAT_DET_LVL_HIGH_SEL_7 default 7 if ESP_VBAT_DET_LVL_HIGH_SEL_7 || ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
config ESP_VBAT_BROWNOUT_DET_LVL config ESP_VBAT_BROWNOUT_DET_LVL
int int