feat(vbat): update vbat charger threshold on p4 revision 3
This commit is contained in:
@@ -89,9 +89,9 @@ menu "Power Supplier"
|
|||||||
Use this option carefully to avoid damage to non-rechargeable batteries.
|
Use this option carefully to avoid damage to non-rechargeable batteries.
|
||||||
|
|
||||||
choice ESP_VBAT_DET_LVL_LOW_SEL
|
choice ESP_VBAT_DET_LVL_LOW_SEL
|
||||||
prompt "VBAT start charging voltage level"
|
prompt "VBAT start charging voltage level (P4 revision < v3.0)"
|
||||||
default ESP_VBAT_DET_LVL_LOW_SEL_6
|
default ESP_VBAT_DET_LVL_LOW_SEL_6
|
||||||
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && ESP32P4_SELECTS_REV_LESS_V3
|
||||||
help
|
help
|
||||||
The brownout detector will start charging when the supply voltage drops below the selected threshold.
|
The brownout detector will start charging when the supply voltage drops below the selected threshold.
|
||||||
This ensures that the power supply is maintained at a stable level.
|
This ensures that the power supply is maintained at a stable level.
|
||||||
@@ -104,10 +104,26 @@ menu "Power Supplier"
|
|||||||
bool "2.42V"
|
bool "2.42V"
|
||||||
endchoice
|
endchoice
|
||||||
|
|
||||||
|
choice ESP_VBAT_DET_LVL_LOW_SEL_V3
|
||||||
|
prompt "VBAT start charging voltage level (P4 revision >= v3.0)"
|
||||||
|
default ESP_VBAT_DET_LVL_LOW_SEL_6_V3
|
||||||
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && !ESP32P4_SELECTS_REV_LESS_V3
|
||||||
|
help
|
||||||
|
The brownout detector will start charging when the supply voltage drops below the selected threshold.
|
||||||
|
This ensures that the power supply is maintained at a stable level.
|
||||||
|
|
||||||
|
config ESP_VBAT_DET_LVL_LOW_SEL_7_V3
|
||||||
|
bool "2.84V"
|
||||||
|
config ESP_VBAT_DET_LVL_LOW_SEL_6_V3
|
||||||
|
bool "2.74V"
|
||||||
|
config ESP_VBAT_DET_LVL_LOW_SEL_5_V3
|
||||||
|
bool "2.64V"
|
||||||
|
endchoice
|
||||||
|
|
||||||
choice ESP_VBAT_DET_LVL_HIGH_SEL
|
choice ESP_VBAT_DET_LVL_HIGH_SEL
|
||||||
prompt "VBAT stop charging voltage level"
|
prompt "VBAT stop charging voltage level (P4 revision < v3.0)"
|
||||||
default ESP_VBAT_DET_LVL_HIGH_SEL_7
|
default ESP_VBAT_DET_LVL_HIGH_SEL_7
|
||||||
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && ESP32P4_SELECTS_REV_LESS_V3
|
||||||
help
|
help
|
||||||
The brownout detector will stop charging when the supply voltage arrives the selected threshold.
|
The brownout detector will stop charging when the supply voltage arrives the selected threshold.
|
||||||
|
|
||||||
@@ -119,6 +135,21 @@ menu "Power Supplier"
|
|||||||
bool "2.42V"
|
bool "2.42V"
|
||||||
endchoice
|
endchoice
|
||||||
|
|
||||||
|
choice ESP_VBAT_DET_LVL_HIGH_SEL_V3
|
||||||
|
prompt "VBAT stop charging voltage level (P4 revision >= v3.0)"
|
||||||
|
default ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
|
||||||
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY && !ESP32P4_SELECTS_REV_LESS_V3
|
||||||
|
help
|
||||||
|
The brownout detector will stop charging when the supply voltage arrives the selected threshold.
|
||||||
|
|
||||||
|
config ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
|
||||||
|
bool "2.84V"
|
||||||
|
config ESP_VBAT_DET_LVL_HIGH_SEL_6_V3
|
||||||
|
bool "2.74V"
|
||||||
|
config ESP_VBAT_DET_LVL_HIGH_SEL_5_V3
|
||||||
|
bool "2.64V"
|
||||||
|
endchoice
|
||||||
|
|
||||||
choice ESP_VBAT_BROWNOUT_DET_LVL_SEL
|
choice ESP_VBAT_BROWNOUT_DET_LVL_SEL
|
||||||
prompt "VBAT brownout voltage level"
|
prompt "VBAT brownout voltage level"
|
||||||
default ESP_VBAT_BROWNOUT_DET_LVL_SEL_5
|
default ESP_VBAT_BROWNOUT_DET_LVL_SEL_5
|
||||||
@@ -144,16 +175,16 @@ menu "Power Supplier"
|
|||||||
config ESP_VBAT_DET_LVL_LOW
|
config ESP_VBAT_DET_LVL_LOW
|
||||||
int
|
int
|
||||||
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
||||||
default 5 if ESP_VBAT_DET_LVL_LOW_SEL_5
|
default 5 if ESP_VBAT_DET_LVL_LOW_SEL_5 || ESP_VBAT_DET_LVL_LOW_SEL_5_V3
|
||||||
default 6 if ESP_VBAT_DET_LVL_LOW_SEL_6
|
default 6 if ESP_VBAT_DET_LVL_LOW_SEL_6 || ESP_VBAT_DET_LVL_LOW_SEL_6_V3
|
||||||
default 7 if ESP_VBAT_DET_LVL_LOW_SEL_7
|
default 7 if ESP_VBAT_DET_LVL_LOW_SEL_7 || ESP_VBAT_DET_LVL_LOW_SEL_7_V3
|
||||||
|
|
||||||
config ESP_VBAT_DET_LVL_HIGH
|
config ESP_VBAT_DET_LVL_HIGH
|
||||||
int
|
int
|
||||||
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
depends on ESP_VBAT_USE_RECHARGEABLE_BATTERY
|
||||||
default 5 if ESP_VBAT_DET_LVL_HIGH_SEL_5
|
default 5 if ESP_VBAT_DET_LVL_HIGH_SEL_5 || ESP_VBAT_DET_LVL_HIGH_SEL_5_V3
|
||||||
default 6 if ESP_VBAT_DET_LVL_HIGH_SEL_6
|
default 6 if ESP_VBAT_DET_LVL_HIGH_SEL_6 || ESP_VBAT_DET_LVL_HIGH_SEL_6_V3
|
||||||
default 7 if ESP_VBAT_DET_LVL_HIGH_SEL_7
|
default 7 if ESP_VBAT_DET_LVL_HIGH_SEL_7 || ESP_VBAT_DET_LVL_HIGH_SEL_7_V3
|
||||||
|
|
||||||
config ESP_VBAT_BROWNOUT_DET_LVL
|
config ESP_VBAT_BROWNOUT_DET_LVL
|
||||||
int
|
int
|
||||||
|
|||||||
Reference in New Issue